MIL-PRF-39016F, PERFORMANCE SPECIFICATION: RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR (01-NOV-2002) [SUPERSEDING MIL-R-39016D]
MIL-PRF-39016F, PERFORMANCE SPECIFICATION: RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR (01-NOV-2002) [SUPERSEDING MIL-R-39016D]., This specification covers the general requirements for electromagnetic, hermetically sealed relays for
use in electronic and communication-type equipment (see 6.1). These relays are designed to operate over the full
range from low level to power switching with contact ratings up to 5 amperes alternating current (ac) or direct current
(dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for
maintenance of qualification based on 100,000 cycles at +125°C under the rated load conditions specified herein.
CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria.
For additional application and caution information, see 6.1.