RADC-TR-67-106, INTERIM REPORT: RF BONDING STUDY (MAR-1967)
RADC-TR-67-106, INTERIM REPORT: RF BONDING STUDY (MAR-1967)., The significant factors affecting bonding impedance at
high frequencies are examined and the reactance of the bonding
structure is shown to be the major contributor. Resonant
effects caused by stray capacitance are examined and an
equivalent circuit is presented to explain the experimentally observed variation with frequency of the bonding impedance.
Several techniques for the reduction of bonding impedance
are described and experimentally evaluated. a.
A technology for continuous visual display of bonding
impedance versus frequency is presented and its suitability
k for field use is noted.